These sterilizers are equipped with a high-flow water recirculation system, thanks to the centrifugal pumps and “double-head multitube” heat exchangers which allow a “water” medium (WFI or PW) to be used as a means of transferring heat to warm up, sterilize and cool down the load. The system ensures optimum heat distribution throughout the entire sterilization phase (temperature deviation below ± 1°C). This process method provides for faster cycles but the treated product comes out still damp. Nevertheless, it remains the preferred method in most cases, due to its simplicity, cost-effectiveness and ease of validation.

  • Circular sterilization chamber with square or rectangular hatches (doors).
  • The TS-OW model boasts a flat/circular cavity that completely envelopes the chamber to quickly and uniformly heat/cool the loads.
  • The TS-OW model is single-walled (no cavity).
  • Some reinforcements are welded onto the outside of the chamber and/or cavity to ensure stability during operating conditions..
  • The chamber is positioned on a base that has been designed specifically to evenly distribute the weight on the floor.
  • The loading trolley-inserting and removing guides are positioned on the bottom of the chamber; they are also height-adjustable.
  • The bottom of the chamber converges towards the drain sump in order to make disposing of the condensate easier.
  • Two 2” tri-clamp ferrules are welded to the chamber for validation purposes (temperature uniformity mapping and pressure tests).
  • All of the chambers internal surfaces are mechanically polished and then subjected to chemical degreasing, pickling and passivation treatments. Surface finish: 0.35 micron.
  • Above-floor or recessed chamber installation possible (depending on the size).

cGMP terminal sterilizers

PHARMA DIVISION

cGMP terminal sterilizer description

The TS-OW autoclaves have been specifically designed to terminally sterilize liquids in sealed containers, such as plastic bags, glass bottles, BFS bottles, syringes, vials, etc. In fact, their design allows for automatic variable pressure compensation based on the temperature difference (ΔT) of the product probes (RTD) inserted on a “sample” container. This type of check prevents the plastic containers from deforming, becoming damaged and changing colour.

LIQUIDS

OVERHEATED WATER

105°C – 121°C

Download the catalogue
Download the technical data sheet
Configure Machine

These sterilisers are equipped with a high-flow water recirculation system, thanks to the centrifugal pumps and “double-head multitube” heat exchangers which allow a “water” medium (WFI or PW) to be used as a means of transferring heat to warm up, sterilise and cool down the load. The system ensures optimum heat distribution throughout the entire sterilisation phase (temperature deviation below ± 1°C). This process method provides for faster cycles but the treated product comes out still damp. Nevertheless, it remains the preferred method in most cases,

due to its simplicity, cost-effectiveness and ease of validation.

  • Circular sterilisation chamber with square or rectangular hatches (doors).
  • The TS-AS model boasts a flat/circular cavity that completely envelopes the chamber to quickly and uniformly heat/cool the loads.
  • The TS-OW model is single-walled (no cavity).
  • Some reinforcements are welded onto the outside of the chamber and/or cavity to ensure stability during operating conditions..
  • The chamber is positioned on a base that has been designed specifically to evenly distribute the weight on the floor.
  • The loading trolley-inserting and removing guides are positioned on the bottom of the chamber; they are also height-adjustable.
  • The bottom of the chamber converges towards the drain sump in order to make disposing of the condensate easier.
  • Two 2” tri-clamp ferrules are welded to the chamber for validation purposes (temperature uniformity mapping and pressure tests).
  • All of the chambers internal surfaces are mechanically polished and then subjected to chemical degreasing, pickling and passivation treatments. Surface finish: 0.35 micron.
  • Above-floor or recessed chamber installation possible (depending on the size).

cGMP terminal sterilisers

PHARMA DIVISION

cGMP terminal steriliser description

The TS-AS and TS-OW autoclaves have been specifically designed to terminally sterilise liquids in sealed containers, such as plastic bags, glass bottles, BFS bottles, syringes, vials, etc. In fact, their design allows for automatic variable pressure compensation based on the temperature difference (ΔT) of the product probes (RTD) inserted on a “sample” container. This type of check prevents the plastic containers from deforming, becoming damaged and changing colour.

LIQUIDS

MIXED AIR + STEAM or SUPERHEATED WATER

105°C – 121°C

Download the catalogue
Download the technical data sheet
Configure Machine

cGMP terminal sterilisers

PHARMA DIVISION

cGMP terminal steriliser description

The TS-AS and TS-OW autoclaves have been specifically designed to terminally sterilise liquids in sealed containers, such as plastic bags, glass bottles, BFS bottles, syringes, vials, etc. In fact, their design allows for automatic variable pressure compensation based on the temperature difference (ΔT) of the product probes (RTD) inserted on a “sample” container. This type of check prevents the plastic containers from deforming, becoming damaged and changing colour.

LIQUIDS

MIXED AIR + STEAM or SUPERHEATED WATER

105°C – 121°C

Download the catalogue
Download the technical data sheet
Configure Machine

These sterilisers are equipped with a high-flow water recirculation system, thanks to the centrifugal pumps and “double-head multitube” heat exchangers which allow a “water” medium (WFI or PW) to be used as a means of transferring heat to warm up, sterilise and cool down the load. The system ensures optimum heat distribution throughout the entire sterilisation phase (temperature deviation below ± 1°C). This process method provides for faster cycles but the treated product comes out still damp. Nevertheless, it remains the preferred method in most cases,

due to its simplicity, cost-effectiveness and ease of validation.

  • Circular sterilisation chamber with square or rectangular hatches (doors).
  • The TS-AS model boasts a flat/circular cavity that completely envelopes the chamber to quickly and uniformly heat/cool the loads.
  • The TS-OW model is single-walled (no cavity).
  • Some reinforcements are welded onto the outside of the chamber and/or cavity to ensure stability during operating conditions..
  • The chamber is positioned on a base that has been designed specifically to evenly distribute the weight on the floor.
  • The loading trolley-inserting and removing guides are positioned on the bottom of the chamber; they are also height-adjustable.
  • The bottom of the chamber converges towards the drain sump in order to make disposing of the condensate easier.
  • Two 2” tri-clamp ferrules are welded to the chamber for validation purposes (temperature uniformity mapping and pressure tests).
  • All of the chambers internal surfaces are mechanically polished and then subjected to chemical degreasing, pickling and passivation treatments. Surface finish: 0.35 micron.
  • Above-floor or recessed chamber installation possible (depending on the size).

We may be small, but we can achieve great things.

Thanks to our customisable after-sales service packages, we offer solutions to suit every need. Choose the one that suits you best!

COMPREHENSIVE AFTER-SALES SUPPORT
INTEGRATED SOLUTIONS
SCHEDULED MAINTENANCE

Customization is quick and easy

Keep up to date with the latest news from the LAST Technology world and let us steer you towards the most suitable service for you!